4-Way Valve Operation in Blow Out Preventer Accumulator (Koomey) Unit

4-way valves in the accumulator (Koomey) unit are used to control the position of Blow Out Preventer (BOP). Today we will go into the detail of 3 positions of 4-way vales in order to see how each position affects to the BOP.

4-way valve operation fb

Read more details about Koomey Unit here =>mechanism of Koomey unit.

Four-Way Vale in Open Position

When the valve is turned into the open position, it directs hydraulic pressure from the manifold into the BOP openning port therefore the BOP is in the open position. The hydraulic fluid in the ram closing chamber will return back to the reservoir tank. Figure 1 illustrates how the hydraulic pressure is lined up to open the BOP.

 4-way-vale-open-rams

Figure 1 – Open position of the 4-way valve

 

Four-Way Vale in Closed Position

The valve is turned into the close position. It means that the hydraulic pressure from the manifold is transferred into the BOP close port. The hydraulic from the opening chamber will return back to the reservoir tank. Figure 2 shows how the hydraulic pressure is lined up to close the BOP.

4-way-vale-closed

Figure 2 – Closed position of the 4-way valve

Four-Way Vale in Block Position

When the four-way valve is left in the block position (central position – Figure 3), there is no hydraulic pressure going into either the “close” or “open” port in the BOP.  You might not know exactly the position of the rams with the block position.

 4-way-vale-block-rams

Figure 3 – Block position of the 4-way valve

In normal drilling operation, you should never leave in the block position. However, the valves can be left in the block position during rig move and repairing operation.

There is one special thing which personnel must consider about the handle of 4-way valve used to operation the bilnd/shear rams (Figure 4). The control handle must be protected to mitigate unintentional operation however it still allows to be remotely operated from the BOP remote control panel.

blind-shear-ram-handle

Figure 4 – Blind/shear ram 4-way valve handle

Reference books: Well Control Books

Related Post

Well Control This page contains well control contents in this site. Basic Calculation Related to Well Control Adjusted maximum allowable shut-in casing press...
Well ballooning (wellbore breathing or micro fract... This topic describes about well ballooning. You may hear several terms besides well ballooning as wellbore breathing or micro fracturing phenomenon. ...
Shut in Procedures and Their Importance Shut in Well Procedures The shut in procedure must be developed and practiced for every rig activity such as: • Shut in while drilling • Shut i...
Understand shoe pressure – Shoe pressure when the ... For this case, we will consider the shoe pressure when the gas kick is passing the casing shoe. See the image below. Let’s apply the hydrostatic pr...
Share the joy
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  

About DrillingFormulas.Com

Working in the oil field and loving to share knowledge.
Tagged , , , . Bookmark the permalink.

6 Responses to 4-Way Valve Operation in Blow Out Preventer Accumulator (Koomey) Unit

  1. inderjeet says:

    Kindly provide more literature on Koomey unit and its operation

  2. Ahmed says:

    Dear,
    Why it called 4 way valve?

  3. fahmilafi says:

    Hi Drilling formulas
    Soory Iam wrong. some confusion to me

    Regards
    F.LAFI DSV.

  4. Vijay says:

    Because it has 4 ports for fluid and 3 selection can be made, that’s why 3 position 4 way valve.

Leave a Reply

Your email address will not be published. Required fields are marked *