Kick Tolerance Factor Calculation

The following formula is the kick tolerance factor.

Kick Tolerance Factor Formula
Where;

Casing shoe TVD in ft

Well depth TVD in ft

Maximum Allowable MW in ppg

Current MW in ppg

For more understanding, let’s try to calculate the kick tolerance factor (KTF) using the following information:

Continue reading

Shut Down Pumps and Weight Up Mud in Driller’s Method

After kick has been circulated out of the well, the mud pumps can be shut down and the well must be secured. While shutting down the pumps, it is a good practice to gradually close the choke instead of suddenly shut in.

You must keep in mind that while shutting down pumps, you must keep casing pressure constant achieved by manipulating the choke. This procedure is to ensure that constant bottom hole pressure is maintained during the shutdown.

Continue reading

Well Control Formulas Part 6

This part of well control formulas will demonstrate you more about some equations frequently used in snubbing operation. In Well Control Formulas Part 5, I show just only some snubbing formulas and this part will show the rest of them.

I wish you would enjoy reading my blog post.

Buoyed Weight of Open Ended Tubulars (Wb),lb

For this formula, you just use the buoyancy factor and multiply it with weight of pipe in the air.


Buoyed Weight of Closed Ended Tubulars without fluid in the pipe (Wb),lb

This formula below is different from the 1st formula because it is used for the closed ended pipe. Weight in the air will be subtracted with buoyancy weight of pipe ran in hole.

Note: 24.5 is conversion factor to make the unit in gallon.

Continue reading

Well Control Formulas Part 5

This part of well control formula series (part#5) will show you following equations: mud increment for volumetric, lube increment for lubricate and bleed, bottle capacity required for koomey unit, volume of usable fluid,  and snubbing force for snubbing operation. Later on, I will show you how to apply equations to particular situation. Anyway this is part 5 and total will be 8 parts.

Mud Increment for Volumetric Method (MI), bbl


Lube Increment for Lubricate and Bleed Method (LI), bbl

Continue reading

Well Control Formulas Part 4

I added some formulas that you must use in the event of well control situation.  Well control formulas part 4 consists of Height of Influx, rate of gas migration, Barite Requirement For Weight-up ,Volume Gain From Slug, Triplex Pump Output, Pump Output, Pump Pressure With New Pump Strokes, and Boyle’s Law

I will keep updating good well control formulas for you. I wish you would enjoy learning about well control formulas.

Height of Influx, ft


Approximate gas migration rate, ft/hr


Sacks of Barite Required For Weight-up, sx

Continue reading